Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/16/19

Message Overview:

Fault Message:

FMQGS COMPUTER INTERFACE/WRG FLT

Fault Code:

2844677PK

Associated CAS:

None

Reporting LRU: Fuel Management and Quantity Gauging Computer (FMQGC)
System Description: 28-41-00
Schematic Diagram: 28-41-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 28-41-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

Fuel Management and Quantity Gauging Computer (FMQGC) does not sense one of the ARINC input signals from the Data Acquisition Units (DAUs).

Possible Causes:

  • Data Acquisition Unit 1 (DAU) (A17)
  • Data Acquisition Unit 2 (DAU) (A18)
  • Fuel Management and Quantity Gauging Computer (FMQGC) (A47)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Connect Electrical Power to the Aircraft AMM 24-00-00-861-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Remove the Electrical Power from the Aircraft AMM 24-00-00-861-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Opening of Non-Thermal Circuit Breakers AMM 24-00-00-863-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Closing of Non-Thermal Circuit Breakers AMM 24-00-00-863-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Electrical/Electronic Safety Precautions AMM 24-00-00-910-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Computer AMM 28-41-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Computer AMM 28-41-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Self-Test of the Computer AMM 28-41-01-740-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Data Acquisition Units (DAU) AMM 31-42-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Data Acquisition Units (DAU) AMM 31-42-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Flight Deck Effect to Fault Correlations AMM 45-45-00-970-821 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Safety Precautions - Maintenance Practices - ALL SPM 20-00-01-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Check if any of the following fault messages appear on the EICAS display:

    1. If YES, select displayed message from menu and perform troubleshooting.
    2. If NO, continue with the next step.

  2. Remove the FMQGC, the DAU 2 to get access to connector A18CP1 and the DAU 1 to get access to connector A17CP1. Perform a continuity check as follows:
    NOTE: While the FMQGC is removed, make sure to inspect the FMQGC and FMQGC tray connectors. Check for damage, bent or pushed back pins and contamination.

    From To Result
    A17CP1-F6 Ground
    A17CP1-G6 Ground
    A18CP1-F6 Ground
    A18CP1-G6 Ground

    1. If there is continuity, replace defective wiring as required and do close out.
    2. If there is no continuity, continue with the next step.

  3. Perform a continuity check as follows:

    From To Result
    A17CP1-F6 A47EP1-A4
    A17CP1-G6 A47EP1-A5
    A18CP1-F6 A47EP1-C4
    A18CP1-G6 A47EP1-C5

    1. If there is no continuity, repair defective wiring as required and do close out.
    2. If there is continuity, continue with next step.

  4. Reinstall the FMQGC making it is fully and properly inserted into place. Is the fault still present?

    1. If YES, continue with the next step.
    2. If NO, do close out.

  5. Swap DAU 1 with DAU 3. Is the fault still present?

    1. If NO, replace DAU 1 and do close out.
    2. If YES, continue with next step.

  6. Swap DAU 2 with DAU 4. Is the fault still present?

    1. If NO, replace DAU 2 and do close out.
    2. If YES, continue with next step.

  7. Replace the FMQGC.
  8. Do close out.