01/28/21
Message Overview:
Message Name:
FMQGC CH A IO#1 PROCESSOR FAIL/WRG
Message Code:
284467APK
Associated CAS:
| Reporting LRU: | Fuel Management and Quantity Gauging Computer (FMQGC) |
| System Description: | 28-41-00 |
| Schematic Diagram: | 28-41-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 28-41-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
Fuel Management and Quantity Gauging Computer (FMQGC) Input/Output Processor has an internal failure.
Possible Causes:
- Fuel Management and Quantity Gauging Computer (FMQGC) (A47)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Computer | AMM 28-41-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Computer | AMM 28-41-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to System Diagnostics | AMM 45-45-00-970-804 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Ensure that both Refuel panels are OFF.
-
Using the EMSCDU, set the FUEL COMP CH A and FUEL COMP CH B circuit breakers to OUT. Wait 10 seconds and set the circuit breakers back to IN. Did the fault clear?
- If YES, do close out.
- If NO, continue to next step.
- Replace the FMQGC computer.