08/15/19
Message Overview:
Fault Message:
HYD RAT PUMP FAIL
Fault Code:
00HRATFL
Associated CAS:
| Reporting LRU: | Hydraulic System 3 |
| System Description: | 29-30-00 |
| Schematic Diagram: | 29-13-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 29-00-05 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Data Acquisition Unit (DAU) 4 (A31) is reporting Hydraulic System 3B pressure below 2400 psi when the Ram Air Turbine (RAT) is deployed.
Possible Causes:
- AC Power Center (ACPC) Secondary Logic Card
- AC Motor Pump (ACMP) 3B Pressure Switch (S40)
- Data Acquisition Unit (DAU) 4 (A31)
- Hydraulic System 3 Accumulator Pressure Circuit
- Ram Air Turbine (RAT)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Quantity Check of the Hydraulic Fluid in the No. 3 Hydraulic System | AMM 12-12-00-610-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Servicing of the Hydraulic System Accumulators | AMM 12-12-00-614-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Ram Air Turbine (RAT) | AMM 24-23-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Ram Air Turbine (RAT) | AMM 24-23-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Release Hydraulic Pressure - No. 3 Hydraulic System | AMM 29-10-00-862-804 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the No. 3 Hydraulic-System AC-Motor-Driven Pumps | AMM 29-13-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the No. 3 Hydraulic-System AC-Motor-Driven Pumps | AMM 29-13-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the No. 3 Hydraulic-System Valve Manifold | AMM 29-13-57-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the No. 3 Hydraulic-System Valve Manifold | AMM 29-13-57-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Hydraulic Pressure Switches | AMM 29-31-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Hydraulic Pressure Switches | AMM 29-31-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Carry out a quantity check of the hydraulic system.
NOTE: Low accumulator service pressure at RAT extension can cause a RAT pump start-up failure. - Pressurize the hydraulic system 3 with the ACMP 3B. Verify the pressure of the hydraulic system 3.
- If the pressure is below 2400 psi, replace the valve manifold and do close out.
- If the pressure is above 2400 psi and the message HYD PUMP 3B FAIL message is not shown, go to step 8.
- If the pressure is above 2400 psi and the message HYD PUMP 3B FAIL message is shown, continue with next step.
- Disconnect the hydraulic system 3B pressure switch connector S40P1 and perform a continuity check between the connectors.
- If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Install a jumper between S40P1-A and S40P1-B and check if message goes away.
- If the message goes away, replace the hydraulic system 3B pressure switch (S40) and do close out.
- If the message is still shown, continue with next step.
- Swap DAU 4 with DAU 3.
- If system checks are good, replace DAU 4 and do close out.
- If fault remains, continue with next step.
- Is the message still present?
- If the message goes away, swap back the DAUs and replace DAU 4 and do close out.
- If message is still present, continue with next step.
- Swap back the DAUs and perform a wiring check between pressure switch S40 and DAU 4.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Do a functional test of the hydraulic system 3 accumulator pressure circuit as follows:
- In the flight compartment, on the HYDRAULIC control panel, set the selection of the ACMP 3B switch to OFF.
- In the hydraulic service compartment 3, do a check of the pressure gauge on the accumulator.
- Record the time (in seconds) for the accumulator pressure indication to reach the service pressure.
NOTE: The time for the pressure to decrease must be 43 seconds or more.
- If the bleed down time is less than 43 seconds, replace the valve manifold and do the functional test of the hydraulic system 3 accumulator pressure circuit as follows:
- In the flight compartment, on the HYDRAULIC control panel, set the selection of the ACMP 3B switch to OFF.
- In the hydraulic service compartment 3, do a check of the pressure gauge on the accumulator.
- Record the time (in seconds) for the accumulator pressure indication to reach the service pressure.
- If the bleed down time is more than 43 seconds, do close out.
- If the time for the pressure to decrease is 43 seconds or more, carry out the hydraulic system 3 (internal leakage check).
NOTE: Too much internal leakage can cause the hydraulic output pressure from the RAT to be low. - If the internal leakage of the hydraulic system 3 is satisfactory, replace the RAT.
- Do close out.