07/22/19
Message Overview:
Fault Message:
DAU1B INVALID / WRG
Fault Code:
3030004HBM
Associated CAS:
| Reporting LRU: | Heater/Brake-Temperature Monitoring Unit (HBMU) 1 |
| System Description: | 30-31-00 |
| Schematic Diagram: | 30-31-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 31-42-05 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
LABEL 270 from Data Acquisition Unit (DAU) 1B to Heater/Brake-Temperature Monitoring Unit (HBMU) 1 has been detected invalid.
Possible Causes:
- Heater/Brake-Temperature Monitoring Unit (HBMU) 1 (A121)
- Data Acquisition Unit (DAU) 1 (A17)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Heater/Brake-Temperature Monitoring Unit (HBMU) | AMM 30-31-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Heater/Brake-Temperature Monitoring Unit (HBMU) | AMM 30-31-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap DAU 1 with DAU 3.
- If system checks are good, replace DAU 1 and do close out.
- If fault remains, continue with next step.
- Replace HBMU 1.
- Do close out.