07/22/19
Message Overview:
Fault Message:
DAU2A INVALID / WRG
Fault Code:
3031010HBM
Associated CAS:
| Reporting LRU: | Heater/Brake-Temperature Monitoring Unit (HBMU) 2 |
| System Description: | 30-31-00 |
| Schematic Diagram: | 30-31-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 31-42-06 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
LABEL 270 from Data Acquisition Unit (DAU) 2A to Heater/Brake-Temperature Monitoring Unit (HBMU) 2 has been detected invalid.
Possible Causes:
- Data Acquisition Unit (DAU) 2 (A18)
- Heater/Brake-Temperature Monitoring Unit (HBMU) 2 (A93)
- Associate Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Heater/Brake-Temperature Monitoring Unit (HBMU) |
AMM 30-31-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Heater/Brake-Temperature Monitoring Unit (HBMU) |
AMM 30-31-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap DAU 2 with DAU 1.
- If system checks are good, replace DAU 2 and do close out.
- If fault remains, continue with next step.
- Replace HBMU 2.
- Do close out.