07/23/19
Message Overview:
Fault Message:
TAT2 HEATER (RIGHT ENG) / WRG
Fault Code:
3031102HBM
Associated CAS:
| Reporting LRU: | Heater/Brake Temperature Monitor Unit (HBMU) 2 |
| System Description: | 30-31-00 |
| Schematic Diagram: | 30-31-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 30-31-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Total Air Temperature (TAT) 2 Heater circuit has been detected opened by Heater/Brake Temperature Monitor Unit (HBMU) 2.
Possible Causes:
- Total Air Temperature (TAT) (E50)
- Heater/Brake Temperature Monitor Unit (HMBU) 2 (A93)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Heater/Brake-Temperature Monitoring Unit (HBMU) | AMM 30-31-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Heater/Brake-Temperature Monitoring Unit (HBMU) | AMM 30-31-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Total Air Temperature (TAT) Probes | AMM 34-11-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Total Air Temperature (TAT) Probes | AMM 34-11-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Perform wiring checks between HBMU 2 and TAT 2 heater.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Measure the resistance of TAT 2 heater. TAT2 heater should be 16-26 ohms at ambient temperature.
- If resistance within range, go to step 4.
- If resistance out of range, continue with next step.
- Replace TAT 2 probe.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace HBMU 2.
- Do close out.