Troubleshooting
arrow By ATA By Message Color By Observed Faults By CAIMS By Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/15/25

Message Overview:

Message Name:

L WINDSHIELD TEMP CONTROL

Message Code:

3040000IN

Associated CAS:

L WINDOW HEAT FAIL
(Caution)

L WSHLD HEAT FAIL
(Caution)

Reporting LRU: Left Windshield and Side Window Temperature-Controller (WTC)
System Description: 30-41-00 - Windshield and Side Window Anti-Icing
Schematic Diagram: 30-41-00 [ Global Express ]  [ G5000 ]  [ Global XRS ] - Windshield Temperature Control System - Electrical Schematic
Wiring Diagram: 30-41-01 [ Global Express ]  [ G5000 ]  [ Global XRS ] - Windshield and Side Window Anti-Icing - Temperature Control (Left)

Message Description:

An internal failure has been detected in the Left Windshield Temperature Controller (L-WTC), accompanied by loss of heating to the left windshield and left window.

NOTE: Troubleshoot accordingly to the Label that triggered the message: first message based on 357 (17, 18,19) and second on 360 (14, 15, 16). Inhibited during Take-off and Landing.

Possible Causes:

  • Left Windshield Temperature Controller (WTC) (A164)
  • Left Windshield (HR9)
  • Left Side Window (HR8)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

Full Throttle Blog/Forum Articles/Infoservice/Newsletter: None

Flight Operation Notifications Manual (FONM): None

Quick Links:

Standard Aircraft Configuration for Maintenance [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM12-00-00-867-801
Connect Electrical Power to the Aircraft [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-00-00-861-801
Electrical/Electronic Safety Precautions [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-00-00-910-801
Electrostatic Discharge Safety Precautions [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-00-00-910-802
Standard Aircraft Configuration for Maintenance [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM12-00-00-867-801
Removal of the Windshield and Side Window Temperature-Controller [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM30-41-01-000-801
Installation of the Windshield and Side Window Temperature-Controller [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM30-41-01-400-801
Removal of the Data Acquisition Units (DAU) [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM31-42-01-000-801
Installation of the Data Acquisition Units (DAU) [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM31-42-01-400-801

Troubleshooting Recommendations:

  1. Disconnect the left WTC and inspect connectors and contacts.

    1. If defects are found, rectify as required.
    2. If no defects are found, reconnect the WTC and continue with next step.

  2. Perform a ground Functional Test.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  3. Interchange the left WTC with the right WTC

    1. If confirmed faulty, replace defective WTC and do close out.
    2. If fault still present on same side, continue with next step.

  4. Carry out a resistance check of the windshield/side window.
    NOTE: The message could be posted for either the windshield or side window, the measurement need to be done on both.

  5. Measure the Heater resistance between T1 and T2 of both the windshield and side window. The total resistance of the anti-fog coating when measured between terminal blocks shall be 11.73 Ω - 15.87 Ω (at 19°C - 29°C).

    1. If resistance within range, continue with next step.
    2. If resistance out of range, replace affected windshield/side window and do close out.

  6. Measure the temperature sensor resistance between S1 and S2 of both the windshield and side window (refer to Windshield and Side Window Temperature Sensor Resistance Chart).

    1. If resistance within range, go to step 8..
    2. If resistance out of range, continue with next step.

  7. Connect spare temperature sensor on left windshield or side window (HR9/HR8).
  8. Do close out.