Message Overview:
Message Name:
L WTC FAIL WND CH W/O REGUL
Message Code:
3040002IN
Associated CAS:
| Reporting LRU: | Left Windshield and Side Window Temperature-Controller (WTC) |
| System Description: | 30-41-00 - Windshield and Side Window Anti-Icing |
| Schematic Diagram: | 30-41-00 [ Global Express ] [ G5000 ] [ Global XRS ] - Windshield Temperature Control System - Electrical Schematic |
| Wiring Diagram: | 30-41-01 [ Global Express ] [ G5000 ] [ Global XRS ] - Windshield and Side Window Anti-Icing - Temperature Control (Left) |
Message Description:
An internal failure has been detected in the Left Windshield Temperature Controller (L-WTC), accompanied by loss of heating to the left side window.
Possible Causes:
- Left Windshield Temperature Controller (WTC) (A164)
- Left Side Window (HR8)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-30-0463 - No Fault Found (NFF) initiative - Windshield Temperature Controller (WTC)
- Windshield Troubleshooting Report to help with windshield temperature controller NFF
Full Throttle Blog/Forum Articles/Infoservice/Newsletter: None
Flight Operation Notifications Manual (FONM): None
Quick Links:
| Standard Aircraft Configuration for Maintenance | [ G5000 ] [ Global Express ] [ Global XRS ] AMM12-00-00-867-801 |
| Connect Electrical Power to the Aircraft | [ G5000 ] [ Global Express ] [ Global XRS ] AMM24-00-00-861-801 |
| Electrical/Electronic Safety Precautions | [ G5000 ] [ Global Express ] [ Global XRS ] AMM24-00-00-910-801 |
| Electrostatic Discharge Safety Precautions | [ G5000 ] [ Global Express ] [ Global XRS ] AMM24-00-00-910-802 |
| Standard Aircraft Configuration for Maintenance | [ G5000 ] [ Global Express ] [ Global XRS ] AMM12-00-00-867-801 |
| Removal of the Windshield and Side Window Temperature-Controller | [ G5000 ] [ Global Express ] [ Global XRS ] AMM30-41-01-000-801 |
| Installation of the Windshield and Side Window Temperature-Controller | [ G5000 ] [ Global Express ] [ Global XRS ] AMM30-41-01-400-801 |
Troubleshooting Recommendations:
- Remove all connectors from the left WTC. Inspect connectors and pins for damage/defects.
- If defects or damage is found, repair/rectify as required and do close out.
- If no defects or damage is found, reconnect the WTC connectors and continue with next step.
- Perform ground Functional Test.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Interchange the left WTC with the right WTC
- If confirmed faulty, replace defective WTC and do close out.
- If fault still present on same side, continue with next step.
- Carry out a resistance check of the side window Heater.
Measure the Heater resistance between T1 and T2. The total resistance of the anti-fog coating when measured between terminal blocks shall be 11.73 Ω - 15.87 Ω (at 19°C - 29°C).- If resistance within range, continue with next step.
- If resistance out of range, replace affected windshield and do close out.
- Measure the temperature sensor resistance (refer to Windshield and Side Window Temperature Sensor Resistance Chart).
- If resistance within range, go to step 7.
- If resistance out of range, continue with next step.
- Connect spare temperature sensor on left side window(HR8).
- Do close out.