07/23/19
Message Overview:
Fault Message:
L WINDOW HEATER OVERCURRENT
Fault Code:
3040011IN
Associated CAS:
| Reporting LRU: | Left Windshield Temperature Controller (WTC) |
| System Description: | 30-41-00 |
| Schematic Diagram: | 30-41-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 30-41-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
A Left Window Heater Overcurrent condition has been detected (Heater Current ≥ 11.07 ±1.01 A).
Possible Causes:
- Left Side Window Heater
- Left Windshield Temperature Controller (WTC) (A164)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-30-0463 - No Fault Found (NFF) initiative - Windshield Temperature Controller (WTC)
- Windshield Troubleshooting Report to help with windshield temperature controller NFF
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Windshield and Side Window Temperature-Controller | AMM 30-41-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Windshield and Side Window Temperature-Controller | AMM 30-41-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Side Windows | AMM 56-10-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Side Windows | AMM 56-10-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Perform wiring checks between Left window heater and L WTC.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Measure the Heater resistance. The total resistance of the anti-fog coating when measured between terminal blocks shall be 27.47 to 33.57 ohms.
- If resistance is within range, go to step 4.
- If resistance is out of range, continue with next step.
- Replace left side window heater.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace L WTC.
- Do close out.