11/21/25
Message Overview:
Message Name:
L WINDOW SENSOR/WIRING [OPEN]
Message Code:
3040014IN
Associated CAS:
| Reporting LRU: | Left Windshield Temperature Controller (WTC) |
| System Description: | 30-41-00 - Windshield And Side Window Anti Icing |
| Schematic Diagram: | [ G5000 ] [ Global Express ] [ Global XRS ] SSM 30-41-00-101 - Windshield Temperature Control System |
| Wiring Diagram: | [ G5000 ] [ Global Express ] [ Global XRS ] WM 30-41-01-1_001 - Sheet 1 - Temperature Control (Left) - ALL [ G5000 ] [ Global Express ] [ Global XRS ] WM 30-41-00-1_001 - Sheet 1 - Left Hand Side - ALL |
Message Description:
The Left Window Temperature Sensor has been detected Open (Sensor Resistance ≥ 600 ±60 Ohms).
Possible Causes:
- Left Window Temperature Sensor
- Left Window (HR8)
- Left Windshield Temperature Controller (WTC) (A164)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-30-0463 - No Fault Found (NFF) initiative - Windshield Temperature Controller (WTC)
- Windshield Troubleshooting Report to help with windshield temperature controller NFF
Full Throttle Blog/Forum Articles/Infoservice/Newsletter: None
Flight Operation Notifications Manual (FONM): None
NOTES:
- There are three temperature sensors installed between the plies of each windshield and side window, one for control and monitoring and two spares (depending on model).
Quick Links:
| Removal of the Windshield and Side Window Temperature-Controller | AMM 30-41-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Windshield and Side Window Temperature-Controller | AMM 30-41-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Side Windows | AMM 56-10-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Side Windows | AMM 56-10-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Remove all connectors from the left WTC. Inspect connectors and pins for damage/defects.
- If no defects or damage is found, reconnect the WTC connectors and continue with next step.
- If defects or damage is found, repair/rectify as required.
- Perform wiring checks between Left Window Temperature Sensor (HR8 S1) and Left Windshield and Side Window Temperature Controller (L WTC) connector A164P1..
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Measure the temperature sensor resistance (refer to Windshield and Side Window Temperature Sensor Resistance Chart).
- If resistance is within range, go to step 5.
- If resistance is out of range, continue with next step.
- Connect sensor wires to spare temperature sensor on the left window.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Interchange WTCs to confirm faulty unit
- If system checks are good, replace faulty unit and do close out.
- If fault remains, continue with next step.
- Replace left side window.
- Do close out.