11/21/25
Message Overview:
Message Name:
L WSHLD HEATER/WIRING [SHORT]
Message Code:
3040018IN
Associated CAS:
| Reporting LRU: | Left Windshield Temperature Controller (WTC) |
| System Description: | 30-41-00 - Windshield And Side Window Anti Icing |
| Schematic Diagram: | [ G5000 ] [ Global Express ] [ Global XRS ] SSM 30-41-00-101 - Windshield Temperature Control System |
| Wiring Diagram: | [ G5000 ] [ Global Express ] [ Global XRS ] WM 30-41-01-1_001 - Sheet 1 - Temperature Control (Left) - ALL [ G5000 ] [ Global Express ] [ Global XRS ] WM 30-41-00-1_001 - Sheet 1 - Left Hand Side - ALL |
Message Description:
The Left Windshield Heater/wiring has been detected short circuit (Heater Current 50±10 A).
Possible Causes:
- Left Windshield (HR9)
- Left Windshield Temperature Controller (WTC) (A164)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-30-0463 - No Fault Found (NFF) initiative - Windshield Temperature Controller (WTC)
Forum Articles/Infoservice/Newsletter: None
Flight Operation Notifications Manual (FONM): None
NOTES:
- Windshield Troubleshooting Report to help with windshield temperature controller NFF
Quick Links:
| Removal of the Windshield and Side Window Temperature-Controller | [ G5000 ] [ Global Express ] [ Global XRS ] AMM30-41-01-000-801 |
| Installation of the Windshield and Side Window Temperature-Controller | [ G5000 ] [ Global Express ] [ Global XRS ] AMM30-41-01-400-801 |
| Removal of the Windshields | [ G5000 ] [ Global Express ] [ Global XRS ] AMM56-10-01-000-801 |
| Installation of the Windshields | [ G5000 ] [ Global Express ] [ Global XRS ] AMM56-10-01-400-801 |
| Wire Repair - Maintenance Practices - ALL | [ G5000 ] [ Global Express ] [ Global XRS ] SPM20-12-10-02 |
Troubleshooting Recommendations:
- Remove all connectors from the left WTC. Inspect connectors and pins for damage/defects.
- If no defects or damage is found, reconnect the WTC connectors and continue with next step.
- If defects or damage is found, repair/rectify as required.
- Perform wiring checks between Left windshield heater (HR9 T1 and T2) and L WTC (A164P2). Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Measure the Heater resistance. The total resistance of the anti-fog coating when measured between terminal blocks shall be 11.73 Ω - 15.87 Ω (at 19°C -29°C).
- If resistance within range, go to step 5.
- If resistance out of range, continue with next step.
- Replace windshield.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Interchange WTCs. Replace if necessary.
- Do close out.