Message Overview:
Fault Message:
R WINDOW HEATER/WIRING [OPEN]
Fault Code:
3041022IN
Associated CAS:
| Reporting LRU: | Right Windshield Temperature-Controller (WTC) |
| System Description: | 30-41-00 |
| Schematic Diagram: | 30-41-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 30-41-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Right Window Heater/wiring has been detected OPEN (Heater Current ≤ 6.12 ±0.68).
Possible Causes:
- Right Window (HR6)
- Right Window Heater
- Right Windshield and Side Window Temperature Controller (WTC) (A165)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-30-0463 - No Fault Found (NFF) initiative - Windshield Temperature Controller (WTC)
- Windshield Troubleshooting Report to help with windshield temperature controller NFF
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Windshield and Side Window Temperature-Controller | AMM 30-41-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Windshield and Side Window Temperature-Controller | AMM 30-41-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Side Windows | AMM 56-10-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Side Windows | AMM 56-10-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Perform wiring checks between right Side Window Heater and R WTC.
- If wiring defects are found, repair defective wiring as required.
- If wiring checks are good, continue with next step.
- Measure the right Side Window Heater resistance. The total resistance of the anti-fog coating when measured between terminal blocks shall be 27.47 to 33.57 ohms.
- If resistance within range, go to step 4.
- If resistance out of range, continue with next step.
- Replace the side window. Is the fault still present?
- If YES, continue with next step.
- If NO, do close out.
- Interchange WTC 2 with WTC 1 and replace if necessary.
NOTE: If the Windshield has visible signs of overheating or delamination caused by overheat, do not interchange the WTCs and simply replace affected WTC. - Do close out.