08/06/19
Message Overview:
Fault Message:
DC1LO/WRG/DAU 1
Fault Code:
3141002DAU
Associated CAS:
| Reporting LRU: | Data Acquisition Unit (DAU) 1 |
| System Description: | 31-40-00 |
| Schematic Diagram: | 31-32-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 31-32-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
DAU is reporting that one of the following is at fault:
-DC VOLTAGE INPUT (See below for identification)
-DAU (INTERNAL FAILURE)
-WIRING BETWEEN DAU AND DC1LO
According to DAU POSITION DC1LO is used for:
DAU 1: HYD SYS #1 PRESSURE TRANSDUCER DAU
Possible Causes:
- Hyd Sys #1 Pressure Transducer DAU
- Data Acquisition Unit (DAU) 1 (A17)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- 700-31-020 - Modification - Flight Data Recording (FDR) System - Installation of the Force Transducer Units (FTU) and Activation of the Crew Force Measuring System (CFMS) 2002
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrostatic Discharge Safety Precautions | AMM 24-00-00-910-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the Crew Force-Measurement System | AMM 31-32-00-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Control Wheel Force-Transducer | AMM 31-32-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Control Wheel Force-Transducer | AMM 31-32-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Forward Equipment-Compartment Access-Panels (131AL/132AR) |
AMM 52-45-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Forward Equipment-Compartment Access Panels (131AL/132AR) |
AMM 52-45-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- None