Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/24/19

Message Overview:

Fault Message:

DC2HI/WRG/DAU 1

Fault Code:

3141003DAU

Associated CAS:

None

Reporting LRU: Data Acquisition Unit (DAU) 1
System Description: 31-40-00
Schematic Diagram: 31-32-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 31-32-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

The Data Acquisition Unit (DAU) 1 senses a malfunction in the Pilot's Control-Wheel Components of the Crew Force-Measurement System.

Possible Causes:

  • Pilot's Control-Wheel Force-Transducer (A253)
  • Data Acquisition Unit (DAU) 1 (A17)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

  • 700-31-020 - Modification - Flight Data Recording (FDR) System - Installation of the Force Transducer Units (FTU) and Activation of the Crew Force Measuring System (CFMS) 2002

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Electrical/Electronic Safety Precautions AMM 24-00-00-910-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Electrostatic Discharge Safety Precautions AMM 24-00-00-910-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Operational Test of the Crew Force-Measurement System AMM 31-32-00-710-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Control Wheel Force-Transducer AMM 31-32-09-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Control Wheel Force-Transducer AMM 31-32-09-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Data Acquisition Units (DAU) AMM 31-42-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Data Acquisition Units (DAU) AMM 31-42-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to Active Faults AMM 45-45-00-970-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Forward Equipment-Compartment Access-Panels
(131AL/132AR)
AMM 52-45-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Forward Equipment-Compartment Access Panels
(131AL/132AR)
AMM 52-45-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Safety Precautions - Maintenance Practices - ALL SPM 20-00-01-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Using PMAT, access CAIMS active faults. Are there any active or stored faults related to the Data Aquisition System displayed?

    1. If YES, perform troubleshooting for the corresponding troubleshooting in SmartFix Plus.
    2. If NO, continue with next step.

  2. Remove DAU 1 to get access to the connector A17AP1 and disconnect A253P1 from CTRL WHL FTU PILOT. Perform a continuity check as follows:

    From To Result
    A17AP1-D11 A253P1-4
    A17AP1-E11 A253P1-5
    A17AP1-SH (shield) A253P1-SH (shield)

    1. If there is no continuity, repair defective wiring as required and do close out.
    2. If there is continuity, continue with next step.

  3. Perform a continuity check as follows:

    From To Result
    A17AP1-D11 Ground
    A17AP1-E11 Ground
    A17AP1-SH (shield) Ground

    1. If there is continuity, repair defective wiring as required and do close out.
    2. If there is no continuity, continue with next step.

  4. Replace DAU 1.
  5. Do close out.