07/25/19
Message Overview:
Fault Message:
FMQGC-A INVALID
Fault Code:
3141087DAU
Associated CAS:
| Reporting LRU: | Data Acquisition Unit (DAU) 1 |
| System Description: | 31-40-00 |
| Schematic Diagram: | 31-42-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 31-42-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Data Acquisition System reports that the Line Replaceable Unit (LRU) label 270 is transmitted from the Fuel Management and Quantity Gauging Computer (FMQGC) with incorrect Source Destination Identifier (SDI) or invalid Sign Status Matrix (SSM).
Possible Causes:
- Fuel Management and Quantity Gauging Computer (FMQGC) (A47)
- Data Acquisition Unit (DAU) 1 (A17)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrostatic Discharge Safety Precautions | AMM 24-00-00-910-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Computer | AMM 28-41-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Computer | AMM 28-41-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Remove DAU 1 to get access to the connector A17CP1 and disconnect the connector A47EP1 from FUEL MANAGEMENT QUANTITY GAUGING COMPUTER. Perform a continuity check as follows:
From To Result A17CP1-A9 A47EP1-A1 A17CP1-A10 A47EP1-A2 A17CP1-SH A47EP1-SH - If there is no continuity, repair or replace defective wiring as required and do close out.
- If there is continuity, continue with the next step.
- Perform a continuity check as follows:
From To Result A17CP1-A9 Ground A17CP1-A10 Ground A17CP1-SH Ground - If there is continuity, repair or replace defective wiring as required and do close out.
- If there is no continuity, continue with the next step.
- Swap DAU 1 with DAU 3.
- If system checks are good, replace DAU 1 and do close out.
- If fault remains, continue with next step.
- Replace FMQGC.