07/25/19
Message Overview:
Fault Message:
FMQGC-A/WRG/DAU #1 INACTIVE
Fault Code:
3141088DAU
Associated CAS:
| Reporting LRU: | Data Acquisition Unit (DAU) 1 |
| System Description: | 28-41-00 |
| Schematic Diagram: | 28-41-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 28-41-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Data Acquisition System does not receive Aeronautical Radio, Inc. (ARINC) 429 data from the Fuel Management and Quantity Gauging Computer (FMQGC).
Possible Causes:
- Fuel Management and Quantity Gauging Computer (FMQGC) (A47)
- Data Acquisition Unit (DAU) 1 (A17)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrostatic Discharge Safety Precautions | AMM 24-00-00-910-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Computer | AMM 28-41-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Computer | AMM 28-41-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Remove DAU 1 to get access to the connector A17CP1 and disconnect the connector A47EP1 from FUEL MANAGEMENT QUANTITY GAUGING COMPUTER. Perform a continuity check as follows:
From To Result A17CP1-F6 A47EP1-A4 A17CP1-G6 A47EP1-A5 A17CP1-SH A47EP1-SH - If there is no continuity, repair or replace defective wiring as required and do close out.
- If there is continuity, continue with the next step.
- Perform a continuity check as follows:
From To Result A17CP1-F6 Ground A17CP1-G6 Ground A17CP1-SH Ground - If there is continuity, repair or replace defective wiring as required and do close out.
- If there is no continuity, continue with the next step.
- Swap DAU 1 with DAU 3.
- If system checks are good, replace DAU 1 and do close out.
- If fault remains, continue with next step.
- Replace FMQGC.
- Do close out.