08/20/19
Message Overview:
Fault Message:
GCU_3/WRG/DAU #1 INACTIVE
Fault Code:
3141099DAU
Associated CAS:
| Reporting LRU: | Generator Control Unit (GCU) 3 |
| System Description: | 24-21-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Fault Description:
Data Acquisition Unit (DAU) 1 is reporting that one of the following is at fault:
- The DAU 1 ARINC Receiver (internal failure)
- The Transmitter of the LRU wired to DAU 1 (see below for LRU identification)
- ARINC wiring interfacing DAU 1 and LRU
- According to DAU 1 position, LRU is
Possible Causes:
- Data Acquisition Unit (DAU) 1 (A17)
- Generator Control Unit (GCU) 3 (A58)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
None
Troubleshooting Recommendations:
None