07/25/19
Message Overview:
Fault Message:
WTC-L/WRG/DAU #1 INACTIVE
Fault Code:
3141111DAU
Associated CAS:
| Reporting LRU: | Data Acquisition Unit (DAU) 1 |
| System Description: | 31-40-00 |
| Schematic Diagram: | 30-41-00 [ Global Express ] [ G5000 ] [ Global XRS ] 31-42-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 30-41-01 [ Global Express ] [ G5000 ] [ Global XRS ] 31-42-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Data Acquisition Unit (DAU) 1 does not receive Aeronautical Radio, Inc. (ARINC) 429 data from the Left Windshield and Side Window Temperature-Controller (WTC).
Possible Causes:
- Left Window Temperature-Controller (WTC) (A164)
- Data Acquisition Unit (DAU) 1 (A17)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrostatic Discharge Safety Precautions | AMM 24-00-00-910-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Windshield and Side Window Temperature-Controller |
AMM 30-41-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Windshield and Side Window Temperature-Controller |
AMM 30-41-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Remove DAU 1 to get access to the connector A17CP1 and disconnect the connector A164P1 from window temperature-controller. Perform a continuity check as follows:
From To Result A17CP1-H6 A164P1-c A17CP1-J6 A164P1-L A17CP1-SH A164P1-SH - If there is no continuity, repair or replace defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Perform a continuity check as follows:
From To Result A17CP1-H6 Ground A17CP1-J6 Ground A17CP1-SH Ground - If there is continuity, repair or replace defective wiring as required and do close out.
- If there is no continuity, continue with next step.
- Swap DAU 1 with DAU 3. Is the fault still present?
- If NO, replace DAU 1 and do close out.
- If YES, continue with next step.
- Replace left window temperature controller.