Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/25/19

Message Overview:

Fault Message:

DAU #1[DO CARD] /WRG[CONN B PIN A4]

Fault Code:

3141133DAU

Associated CAS:

None

Reporting LRU: Data Acquisition Unit (DAU) 1
System Description: 31-40-00
Schematic Diagram: 31-42-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 31-42-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

The Data Acquisition Unit (DAU) 1 senses a fault related to the RH ENG VLV OPEN Lamp Driver.

Possible Causes:

  • Lamp Dimmer Power Supply (LDPS) 1 (A145)
  • Data Acquisition Unit (DAU) 1 (A17)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Connect Electrical Power to the Aircraft AMM 24-00-00-861-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Remove the Electrical Power from the Aircraft AMM 24-00-00-861-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Electrical/Electronic Safety Precautions AMM 24-00-00-910-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Electrostatic Discharge Safety Precautions AMM 24-00-00-910-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Data Acquisition Units (DAU) AMM 31-42-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Data Acquisition Units (DAU) AMM 31-42-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Lamp-Dimmer Power Supplies AMM 31-43-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Lamp-Dimmer Power Supplies AMM 31-43-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to Active Faults AMM 45-45-00-970-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to Stored Faults AMM 45-45-00-970-803 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Safety Precautions - Maintenance Practices - ALL SPM 20-00-01-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Replacement of the Bulb for the Switch/Light SPM 20-11-05-960-803 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Check if the RH ENG VLV OPEN light on the OIL REPLENISHMENT control panel comes on by performing the following steps:

    1. In the flight compartment, on the OIL REPLENISHMENT control panel, momentarily push the power SYSTEM ON switch/light.
    2. Check if the switch/lights come on for a three second lamp test.
      NOTE: After three seconds, all the lights go out except the SYSTEM ON switch/light. Under certain low oil conditions, the LO OIL switch/light for either engine or the APU may remain on.

  2. Check if the RH ENG VLV OPEN annunciator light on the control panel comes on.

    1. If the annunciator light on the control panel does not come on, replace the defective bulbs and do close out.
    2. If the annunciator light on the control panel comes on, continue with next step.

  3. Remove the DAU 1 to get access to the connector A17BP1 and the lamp dimmer power supply 1 to get access to the connector A145P1. Perform a continuity check as follows:

    From To Result
    A17BP1-A4 A145P1-C

    1. If there is no continuity, repair or replace defective wiring as required and do close out.
    2. If there is continuity, continue with next step.

  4. Perform a continuity check as follows:

    From To Result
    A17BP1-A4 Ground

    1. If there is continuity, repair or replace defective wiring as required and do close out.
    2. If there is no continuity, continue with next step.

  5. Swap DAU 1 with DAU 3. Is the fault still present?

    1. If NO, replace DAU 1 and do close out.
    2. If YES, continue with next step.

  6. Replace the lamp dimmer power supply 1.
  7. Do close out.