07/25/19
Message Overview:
Fault Message:
DAU #1[DO CARD] /WRG[CONN B PIN A6]
Fault Code:
3141135DAU
Associated CAS:
| Reporting LRU: | Data Acquisition Unit (DAU) 1 |
| System Description: | 31-40-00 |
| Schematic Diagram: | 31-42-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 31-42-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Data Acquisition Unit (DAU) 1 senses a fault related to the APU LO OIL Lamp Driver.
Possible Causes:
- Lamp Dimmer Power Supply (LDPS) 1 (A145)
- Data Acquisition Unit (DAU) 1 (A17)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Remove the Electrical Power from the Aircraft | AMM 24-00-00-861-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrostatic Discharge Safety Precautions | AMM 24-00-00-910-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Lamp-Dimmer Power Supplies | AMM 31-43-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Lamp-Dimmer Power Supplies | AMM 31-43-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Stored Faults | AMM 45-45-00-970-803 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Replacement of the Bulb for the Switch/Light | SPM 20-11-05-960-803 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Check if the APU LO OIL light on the OIL REPLENISHMENT control panel comes on by performing the following steps:
- In the flight compartment, on the OIL REPLENISHMENT control panel, momentarily push the power SYSTEM ON switch/light.
- Check if the switch/lights come on for a three second lamp test.
NOTE: After three seconds, all the lights go out except the SYSTEM ON switch/light. Under certain low oil conditions, the LO OIL switch/light for either engine or the APU may remain on.
- Check if the APU LO OIL annunciator light on the control panel comes on.
- If the annunciator light on the control panel does not come on, replace the defective bulbs.
- If the annunciator light on the control panel comes on, continue with next step.
- Remove the DAU 1 to get access to the connector A17BP1 and the lamp dimmer power supply 1 to get access to the connector A145P1. Perform a continuity check as follows:
From To Result A17BP1-A6 A145P1-C - If there is no continuity, repair or replace defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Perform a continuity check as follows:
From To Result A17BP1-A6 Ground - If there is continuity, repair or replace defective wiring as required and do close out.
- If there is no continuity, continue with next step.
- Swap DAU 1 with DAU 3. Is the fault still present?
- If NO, replace DAU 1 and do close out.
- If YES, continue with next step.
- Replace the lamp dimmer power supply 1.
- Do close out.