Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/26/19

Message Overview:

Fault Message:

POT2HI/WRG/DAU 2

Fault Code:

3143015DAU

Associated CAS:

None

Reporting LRU: Data Acquisition Unit (DAU) 2
System Description: 31-40-00
Schematic Diagram: 21-31-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
31-42-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 21-31-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]
31-42-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

The Data Acquisition Unit (DAU) 2 senses that the OFV POSITION analog signal from the manual Channel of the Outflow Valve 2 is out of range.

Possible Causes:

  • AFT Outflow Valve 2 (L9)
  • Data Acquisition Unit (DAU) 2 (A18)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Outflow Valves AMM 21-31-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Outflow Valves AMM 21-31-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Connect Electrical Power to the Aircraft AMM 24-00-00-861-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Remove the Electrical Power from the Aircraft AMM 24-00-00-861-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Opening of Non-Thermal Circuit Breakers AMM 24-00-00-863-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Closing of Non-Thermal Circuit Breakers AMM 24-00-00-863-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Electrical/Electronic Safety Precautions AMM 24-00-00-910-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Data Acquisition Units (DAU) AMM 31-42-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Data Acquisition Units (DAU) AMM 31-42-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to Active Faults AMM 45-45-00-970-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to Stored Faults AMM 45-45-00-970-803 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the External Avionics-Compartment Access-Panel (140BB) AMM 52-45-11-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the External Avionics-Compartment Access-Panel (140BB) AMM 52-45-11-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Aft Fuselage Floor-Panels (251ALF, 251BLF, 251CLF,
251DLF, 251ELF, 251FLF, 251GLF, 251HLF, 252BRF, 252CRF,
252DRF, 252ERF, 252FRF, 252GRF, 252HRF)
AMM 53-41-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Aft Fuselage Floor-Panels (251ALF, 251BLF, 251CLF,
251DLF, 251ELF, 251FLF, 251GLF, 251HLF, 252BRF, 252CRF,
252DRF, 252ERF, 252FRF, 252GRF, 252HRF)
AMM 53-41-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Safety Precautions - Maintenance Practices - ALL SPM 20-00-01-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Disconnect the connector L9P2 from outflow valve 2 and remove the DAU 2 to get access to connector A18AP1. Perform a continuity check as follows:

    From To Result
    L9P2-3 A18AP1-E14
    L9P2-4 A18AP1-D14
    L9P2-5 A18AP1-C14
    L9P2-Shield A18AP1-Shield

    1. If there is no continuity, repair or replace defective wiring as required and do close out.
    2. If there is continuity, continue with next step.

  2. Perform a continuity check as follows:

    From To Result
    L9P2-3 Ground
    L9P2-4 Ground
    L9P2-5 Ground

    1. If there is continuity, repair or replace defective wiring as required and do close out.
    2. If there is no continuity, continue with next step.

  3. Replace outflow valve 2. Is the fault still present?

    1. If NO, do close out.
    2. If YES, continue with next step.

  4. Replace DAU 2.
  5. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.