08/20/19
Message Overview:
Fault Message:
BMC_1B/WRG/DAU #2 INACTIVE
Fault Code:
3143050DAU
Associated CAS:
| Reporting LRU: | Data Acquisition Unit (DAU) 2 |
| System Description: | 31-40-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Fault Description:
Data Acquisition Unit (DAU) 2 is reporting that one of the following is at fault:
- The DAU ARINC receiver (internal failure)
- The transmitter of the LRU wired to DAU (see below for identification)
- ARINC wiring interfacing DAU and LRU
According to DAU position, LRU is.
Possible Causes:
- Data Acquisition Unit (DAU) 2 (A18)
- Bleed Management Controller 1 (A69)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
None
Troubleshooting Recommendations:
None