Message Overview:
Fault Message:
HBMU_2/WRG/DAU #2 INACTIVE
Fault Code:
3143086DAU
Associated CAS:
| Reporting LRU: | Data Acquisition Unit (DAU) 2 |
| System Description: | 31-40-00 |
| Schematic Diagram: | 31-42-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 31-42-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Data Acquisition Unit (DAU) 2 is not receiving valid data from the Heater/Brake Temperature Monitor Unit (HBMU) 2.
Possible Causes:
- Data Acquisition Unit (DAU) 2 (A18)
- Heater/Brake Temperature Monitor Unit (HBMU) 2 (A93)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Remove the Electrical Power from the Aircraft | AMM 24-00-00-861-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Opening of Non-Thermal Circuit Breakers | AMM 24-00-00-863-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Closing of Non-Thermal Circuit Breakers | AMM 24-00-00-863-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the Air Data Probes and Sensors Anti-Ice System |
AMM 30-31-00-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Heater/Brake-Temperature Monitoring Unit (HBMU) |
AMM 30-31-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Heater/Brake-Temperature Monitoring Unit (HBMU) |
AMM 30-31-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the Data Acquisition System | AMM 31-42-00-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Stored Faults | AMM 45-45-00-970-803 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Flight Deck Effect to Fault Correlations | AMM 45-45-00-970-821 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Check if the internal fault for the ADC, DAU, EEC or EMS CDU is displayed.
- If YES, perform the applicable troubleshooting and do close out.
- If NO, continue with the next step.
- Disconnect the connector A93P2 from HBMU 2 and remove DAU 2 to get access to the connector A18CP1. Perform a continuity check as follows:
From To Result A93P2-5 A18CP1-A9 A93P2-6 A18CP1-A10 A93P2-33 A18CP1-K1 A93P2-34 A18CP1-K2 - If there is no continuity, repair or replace defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Perform a continuity check as follows:
From To Result A93P2-5 Ground A93P2-6 Ground A93P2-K1 Ground A93P2-K2 Ground - If there is continuity, repair or replace defective wiring as required and do close out.
- If there is no continuity, continue with next step.
- Swap HBMU 2 with HBMU 3.
- If system checks are good, replace HBMU 2 and do close out.
- If fault remains, continue with next step.
- Replace DAU 2.
- Do close out.