07/29/19
Message Overview:
Fault Message:
DAU #2[DO CARD]/WRG[CONN A PIN K14]
Fault Code:
3143128DAU
Associated CAS:
| Reporting LRU: | Data Acquisition Unit (DAU) 2 |
| System Description: | 31-40-00 |
| Schematic Diagram: | 31-42-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 31-42-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Data Acquisition Unit (DAU) 2 senses a fault related to the R FUEL RECIRC ON IND Lamp Driver for the FUEL Panel.
Possible Causes:
- Lamp Dimmer Power Supply (LDPS) 3 (A147)
- Data Acquisition Unit (DAU) 2 (A18)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Remove the Electrical Power from the Aircraft | AMM 24-00-00-861-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrostatic Discharge Safety Precautions | AMM 24-00-00-910-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Lamp-Dimmer Power Supplies | AMM 31-43-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Lamp-Dimmer Power Supplies | AMM 31-43-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Stored Faults | AMM 45-45-00-970-803 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Replacement of the Bulb for the Switch/Light | SPM 20-11-05-960-803 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Check if the R FUEL RECIRC ON light on the FUEL panel comes on by performing the following steps:
- In the flight compartment, on the COCKPIT LIGHTS (INTEGRAL) control panel, set the PBA switch to BRT.
- In the flight compartment, on the EMS CDU, momentarily push the SYSTEM TEST pushbutton. Check if the SYSTEM TEST menu shows on the display.
- Set the left vertical pushbutton to LAMP TEST 1. Check if the LAMP TEST 1 OFF is highlighted.
- Set the right vertical pushbutton to LAMP TEST 1. Check if the OFF changes to TEST.
- Check if the R FUEL RECIRC ON annunciator light on the control panel comes on.
- If the annunciator light on the control panel is not comes on, replace the defective bulbs and do close out.
- If the annunciator light on the control panel is comes on, continue with next step.
- Remove the DAU 2 to get access to the connector A18AP1 and the lamp dimmer power supply 3 to get access to the connector A147P1. Perform a continuity check as follows:
From To Result A18AP1-K14 A147P1-C - If there is no continuity, repair or replace defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Perform a continuity check as follows:
From To Result A18AP1-K14 Ground - If there is continuity, repair or replace defective wiring as required and do close out.
- If there is no continuity, continue with next step.
- Swap DAU 2 with DAU 4.
- If system checks are good, replace DAU 2 and do close out.
- If fault remains, continue with next step.
- Replace the Lamp Dimmer Power Supply 3.