08/21/19
Message Overview:
Fault Message:
RVT 2/WRG/DAU 2
Fault Code:
3144041DAU
Associated CAS:
| Reporting LRU: | Data Acquisition Unit (DAU) 2 |
| System Description: | 31-40-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Fault Description:
Data Acquisition Unit (DAU) 2 is reporting that one of the following is at fault:
- Rotary Variable Transformer (see below for identification)
- DAU 2 (internal failure)
- Wiring between DAU 2 and RVT 2
According to DAU 2 position RVT 2 is used for:
- DAU 1: LEFT ELEVATOR SURFACE PO
Possible Causes:
- Data Acquisition Unit (DAU) 2 (A18)
- Rotary Variable Transformer (RVT) 2
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
None
Troubleshooting Recommendations:
None