08/21/19
Message Overview:
Fault Message:
EMS_CDU_2B/WRG/DAU #2 INACTIVE
Fault Code:
3144082DAU
Associated CAS:
| Reporting LRU: | Data Acquisition Unit (DAU) 2 |
| System Description: | 31-40-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Fault Description:
Data Acquisition Unit (DAU) 2 is reporting that one of the following is at fault:
- The DAU 2 ARINC Receiver (internal failure)
- The Transmitter of the LRU wired to DAU 2 (see below for identification)
- ARINC wiring interfacing DAU 2 and LRU
According to DAU 2 position, LRU is
Possible Causes:
- Data Acquisition Unit (DAU) 2 (A18)
- Electrical Management System Control and Display Unit (EMS CDU) 2 (A91)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
None
Troubleshooting Recommendations:
None