Message Overview:
Fault Message:
DAU 2B POWER FAULT
Fault Code:
3144169DAU
Associated CAS:
| Reporting LRU: | Data Acquisition Unit (DAU) 2 |
| System Description: | 31-40-00 |
| Schematic Diagram: | 31-42-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 31-42-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Data Acquisition Unit (DAU) 2 senses a fault in the System that supplies its power.
Possible Causes:
- Secondary-Power Distribution Assembly (SPDA) 1 (A13)
- Data Acquisition Unit (DAU) 2 (A18)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Remove the Electrical Power from the Aircraft | AMM 24-00-00-861-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Opening of Non-Thermal Circuit Breakers | AMM 24-00-00-863-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Closing of Non-Thermal Circuit Breakers | AMM 24-00-00-863-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrostatic Discharge Safety Precautions | AMM 24-00-00-910-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the Secondary-Power Distribution Assembly 1 | AMM 24-62-01-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the External Avionics-Compartment Access-Panel (140BB) |
AMM 52-45-11-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the External Avionics-Compartment Access-Panel (140BB) |
AMM 52-45-11-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- On the EMS CDU, make sure that DAU CH 2B is set to "IN".
- If the circuit breaker is not set to "IN", investigate the reason and if possible, set it to "IN" and do close out.
- If the circuit breaker is set to "IN", continue with next step.
- Remove the DAU 2 and perform a 28 VDC voltage check on DAU 2 connector as follows:
DAU 2 Expected Result Result A18BP1-A14 28 VDC - If there is no 28 VDC, go to step 4.
- If there is 28 VDC, continue with next step.
- Perform a continuity check as follows:
From To Result A18BP1-A15 Ground A18BP1-K15 Ground - If there is continuity, go to step 6.
- If there is no continuity, repair or replace defective wiring as required and do close out.
- Perform a continuity check as follows:
From To Result A18BP1-A14 A13P3-J A18BP1-A15 Ground A18BP1-K15 Ground - If there is no continuity, repair or replace defective wiring as required and do close out.
- If there is continuity, continue with the next step.
- Perform a continuity check as follows:
From To Result A18BP1-A14 Ground - If there is continuity, repair or replace defective wiring as required and do close out.
- If there is no continuity, investigate the SPDA power source and do close out.
- Replace DAU 2.
- Do close out.