Message Overview:
Fault Message:
DC4LO/WRG/DAU 3
Fault Code:
3145008DAU
Associated CAS:
| Reporting LRU: | Data Acquisition Unit (DAU) 3 |
| System Description: | 31-40-00 |
| Schematic Diagram: | 31-32-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 31-32-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Data Acquisition Unit (DAU) 3 senses a malfunction in the Copilot’s LH Rudder Pedal Components of the Crew Force-Measurement System.
Possible Causes:
- Copilot’s LH Rudder-Pedal Force-Transducer (A258)
- Data Acquisition Unit (DAU) 3 (A30)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- 700-31-020 - Modification - Flight Data Recording (FDR) System - Installation of the Force Transducer Units (FTU) and Activation of the Crew Force Measuring System (CFMS) 2002
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrostatic Discharge Safety Precautions | AMM 24-00-00-910-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the Crew Force-Measurement System | AMM 31-32-00-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Rudder Pedal Force-Transducer | AMM 31-32-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Rudder Pedal Force-Transducer | AMM 31-32-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Forward Equipment-Compartment Access-Panels (131AL/132AR) |
AMM 52-45-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Forward Equipment-Compartment Access Panels (131AL/132AR) |
AMM 52-45-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Using PMAT, access CAIMS active faults. Are there any active or stored faults related to the Data Aquisition System displayed?
- If YES, perform troubleshooting for the corresponding troubleshooting in SmartFix Plus and do clsee out.
- If NO, continue with next step.
- Remove DAU 3 to get access to the connector A30AP1 and disconnect A258P1 from RDR PDL FTU COPILOT L. Perform a continuity check as follows:
From To Result A30AP1-G8 A258P1-4 A30AP1-H8 A258P1-5 A30AP1-SH A258P1-SH - If there is no continuity, repair or replace defective wiring as required and do close out.
- If there is continuity, continue with the next step.
- Perform a continuity check as follows:
From To Result A30AP1-G8 Ground A30AP1-H8 Ground A30AP1-SH Ground - If there is continuity, repair or replace defective wiring as required and do close out.
- If there is no continuity, continue with the next step.
- Swap DAU 3 with DAU 1.
- If system checks are good, replace DAU 3 and do close out.
- If fault remains, continue with next step.
- Replace the Copilot’s LH Rudder-Pedal Force-Transducer.
- Do close out.