background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults By CAIMS By Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/30/19

Message Overview:

Fault Message:

POTEX 3/WRG/DAU 3

Fault Code:

3145023DAU

Associated CAS:

None

Reporting LRU: Data Acquisition Unit (DAU) 3
System Description: 31-40-00
Schematic Diagram: 29-13-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
31-42-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 29-00-05 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

The Hydraulic Quantity Transmitter does not operate because of an incorrect excitation voltage.

NOTE: The Hydraulic Quantity Transmitter is installed in and is a part of the Hydraulic System Reservoir. The Data Acquisition Unit (DAU) supplies the excitation voltage.

Possible Causes:

  • Hydraulic System 3 Reservoir Quantity Transducer (MT145)
  • Data Acquisition Unit (DAU) 3 (A30)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Remove the Electrical Power from the Aircraft AMM 24-00-00-861-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Opening of Non-Thermal Circuit Breakers AMM 24-00-00-863-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Closing of Non-Thermal Circuit Breakers AMM 24-00-00-863-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Electrical/Electronic Safety Precautions AMM 24-00-00-910-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Electrostatic Discharge Safety Precautions AMM 24-00-00-910-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the No. 3 Hydraulic System Reservoir AMM 29-13-29-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the No. 3 Hydraulic System Reservoir AMM 29-13-29-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Data Acquisition Units (DAU) AMM 31-42-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Data Acquisition Units (DAU) AMM 31-42-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to Active Faults AMM 45-45-00-970-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Aft Equipment-Compartment
Door (311BB)
AMM 52-41-00-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Aft Equipment-Compartment
Door (311BB)
AMM 52-41-00-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the External Avionics-Compartment
Access-Panel (140BB)
AMM 52-45-11-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the External Avionics-Compartment
Access-Panel (140BB)
AMM 52-45-11-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Safety Precautions - Maintenance Practices - ALL SPM 20-00-01-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Remove aft equipment-compartment door and external avionics-compartment access-panel.
  2. Remove the DAU 3 to get access to connectors. Perform a continuity check as follows:

    From To Result
    MT145P1-D A30BP1-H3
    MT145P1-A A30BP1-G3
    MT145P1-B A30BP1-J3
    MT145P1-SH A30BP1-SH

    1. If there is no continuity, repair or replace defective wiring as required and do close out.
    2. If there is continuity, continue with the next step.

  3. Perform a continuity check as follows:

    From To Result
    A30BP1-H3 Ground
    A30BP1-G3 Ground
    A30BP1-J3 Ground
    A30BP1-SH Ground

    1. If there is continuity, repair or replace defective wiring as required and do close out.
    2. If there is no continuity, continue with the next step.

  4. Swap DAU 3 with DAU 4. Is the fault still present?

    1. If NO, replace DAU 3 and do close out.
    2. If YES, continue with next step.

  5. Replace the Hydraulic System 3 Reservoir Quantity Transducer.
  6. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.