07/31/19
Message Overview:
Fault Message:
SFCU_1 INVALID
Fault Code:
3145044DAU
Associated CAS:
| Reporting LRU: | Data Acquisition Unit (DAU) 3 |
| System Description: | 31-40-00 |
| Schematic Diagram: | 27-50-00 [ Global Express ] [ G5000 ] [ Global XRS ] 31-42-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-50-07 [ Global Express ] [ G5000 ] [ Global XRS ] 31-42-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Data Acquisition Unit (DAU) 3 reports that the LRU on label 270 is transmitted from the Slat/Flap Control Unit (SFCU) 1 with incorrect Source Destination Identifier (SDI) or invalid Sign Status Matrix (SSM).
Possible Causes:
- Data Acquisition Unit (DAU) 3 (A30)
- Slat/Flap Control Unit (SFCU) 1 (A124)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Remove the Electrical Power from the Aircraft | AMM 24-00-00-861-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Slat/Flap Control Unit (SFCU) | AMM 27-51-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Slat/Flap Control Unit (SFCU) | AMM 27-51-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Stored Faults | AMM 45-45-00-970-803 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Remove DAU 3 to get access to the connector A30CP1 and SFCU 1 to get access to the connector A124AP1. Perform a continuity check as follows:
From To Result A30CP1-H8 A124AP1-66 A30CP1-J8 A124AP1-79 - If there is no continuity, repair or replace defective wiring as required and do close out.
- If there is continuity, continue with the next step.
- Perform a continuity check as follows:
From To Result A30CP1-H8 Ground A30CP1-J8 Ground - If there is continuity, repair or replace defective wiring as required and do close out.
- If there is no continuity, continue with the next step.
- Swap DAU 3 with DAU 1. Is the fault still present?
- If NO, replace DAU 3 and do close out.
- If YES, continue with the next step.
- Replace the SFCU 1.
- Do close out.