Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/31/19

Message Overview:

Fault Message:

SFCU_1/WRG/DAU #3 INACTIVE

Fault Code:

3145045DAU

Associated CAS:

None

Reporting LRU: Data Acquisition Unit (DAU) 3
System Description: 31-40-00
Schematic Diagram: 27-50-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
31-42-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 27-50-07 [ Global Express ]  [ G5000 ]  [ Global XRS ]
31-42-03 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

The Data Acquisition Unit (DAU) 3 does not receive ARINC 429 data from the Slat/Flap Control Unit (SFCU) 1.

Possible Causes:

  • Data Acquisition Unit (DAU) 3 (A30)
  • Slat/Flap Control Unit (SFCU) 1 (A124)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Connect Electrical Power to the Aircraft AMM 24-00-00-861-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Remove the Electrical Power from the Aircraft AMM 24-00-00-861-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Electrical/Electronic Safety Precautions AMM 24-00-00-910-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Slat/Flap Control Unit (SFCU) AMM 27-51-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Slat/Flap Control Unit (SFCU) AMM 27-51-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Data Acquisition Units (DAU) AMM 31-42-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Data Acquisition Units (DAU) AMM 31-42-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to Active Faults AMM 45-45-00-970-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to Stored Faults AMM 45-45-00-970-803 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Safety Precautions - Maintenance Practices - ALL SPM 20-00-01-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Remove DAU 3 to get access to the connector A30CP1 and SFCU 1 to get access to the connector A124AP1. Perform a continuity check as follows:

    From To Result
    A30CP1-H8 A124AP1-66
    A30CP1-J8 A124AP1-79

    1. If there is no continuity, repair or replace defective wiring as required and do close out.
    2. If there is continuity, continue with the next step.

  2. Perform a continuity check as follows:

    From To Result
    A30CP1-H8 Ground
    A30CP1-J8 Ground

    1. If there is continuity, repair or replace defective wiring as required and do close out.
    2. If there is no continuity, continue with the next step.

  3. Swap DAU 3 with DAU 1. Is the fault still present?

    1. If NO, replace DAU 3 and do close out.
    2. If YES, continue with the next step.

  4. Replace the SFCU 1.
  5. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.