07/31/19
Message Overview:
Fault Message:
APU FADEC INVALID
Fault Code:
3145087DAU
Associated CAS:
| Reporting LRU: | Data Acquisition Unit (DAU) 3 |
| System Description: | 31-40-00 |
| Schematic Diagram: | 31-42-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | None |
Fault Description:
The Data Acquisition System reports that the LRU label 270 is transmitted with incorrect Source Destination Identifier (SDI) or invalid Sign Status Matrix (SSM).
Possible Causes:
- Auxiliary Power Unit Full Authority Digital Engine Controller (FADEC) (A108)
- Data Acquisition Unit (DAU) 3 (A30)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Full-Authority Digital Engine-Controller (FADEC) | AMM 49-61-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Full-Authority Digital Engine-Controller (FADEC) | AMM 49-61-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Using PMAT, access CAIMS active faults. Are there any active or stored faults related to the Data Aquisition System displayed?
- If YES, perform troubleshooting for the corresponding troubleshooting in SmartFix Plus.
- If NO, continue with next step.
- Check if there are any "INACTIVE" faults for the same LRU.
- If YES, ignore the APU FADEC INVALID fault message and identify the cause for the "INACTIVE" conditions first.
- If NO, continue with next step.
- Swap DAU 3 with DAU 1. Is the fault still present?
- If NO, replace DAU 3 and do close out.
- If YES, continue with next step.
- Replace the FADEC.
- Do close out.