background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults By CAIMS By Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/31/19

Message Overview:

Fault Message:

APU FADEC INVALID

Fault Code:

3145087DAU

Associated CAS:

None

Reporting LRU: Data Acquisition Unit (DAU) 3
System Description: 31-40-00
Schematic Diagram: 31-42-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: None

Fault Description:

The Data Acquisition System reports that the LRU label 270 is transmitted with incorrect Source Destination Identifier (SDI) or invalid Sign Status Matrix (SSM).

Possible Causes:

  • Auxiliary Power Unit Full Authority Digital Engine Controller (FADEC) (A108)
  • Data Acquisition Unit (DAU) 3 (A30)

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Data Acquisition Units (DAU) AMM 31-42-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Data Acquisition Units (DAU) AMM 31-42-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to Active Faults AMM 45-45-00-970-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Full-Authority Digital Engine-Controller (FADEC) AMM 49-61-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Full-Authority Digital Engine-Controller (FADEC) AMM 49-61-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Using PMAT, access CAIMS active faults. Are there any active or stored faults related to the Data Aquisition System displayed?

    1. If YES, perform troubleshooting for the corresponding troubleshooting in SmartFix Plus.
    2. If NO, continue with next step.

  2. Check if there are any "INACTIVE" faults for the same LRU.

    1. If YES, ignore the APU FADEC INVALID fault message and identify the cause for the "INACTIVE" conditions first.
    2. If NO, continue with next step.

  3. Swap DAU 3 with DAU 1. Is the fault still present?

    1. If NO, replace DAU 3 and do close out.
    2. If YES, continue with next step.

  4. Replace the FADEC.
  5. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.