08/22/19
Message Overview:
Fault Message:
GCU_4 INVALID
Fault Code:
3145098DAU
Associated CAS:
| Reporting LRU: | Data Acquisition Unit (DAU) |
| System Description: | 24-21-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Fault Description:
Data Acquisition Unit (DAU) is reporting that the Line Replaceable Unit (LRU) is transmitting label 270 with incorrect Source Destination Identifier (SDI) or invalid SSM (failure warning or no computed data). If this fault shows at the same time as an "INACTIVE" fault for the same LRU, ignore this fault because the "INACTIVE" condit.
Possible Causes:
- Data Acquisition Unit (DAU)
- Generator Control Unit (GCU) 4 (A59)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
None
Troubleshooting Recommendations:
None