08/22/19
Message Overview:
Fault Message:
GCU_4/WRG/DAU #3 INACTIVE
Fault Code:
3145099DAU
Associated CAS:
| Reporting LRU: | Data Acquisition Unit (DAU) 3 |
| System Description: | 31-40-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Fault Description:
Data Acquisition Unit (DAU) 3 is reporting that one of the following is at fault:
- The DAU 3 ARINC Receiver (internal failure)
- The Transmitter of the LRU wired to DAU 3 (see below for LRU identification)
- ARINC wiring interfacing DAU 3 and LRU
According to DAU 3 position, LRU is
Possible Causes:
- Data Acquisition Unit (DAU) 3 (A30)
- Generator Control Unit (GCU) 4 (A59)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
None
Troubleshooting Recommendations:
None