Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/31/19

Message Overview:

Fault Message:

DAU #3[DO CARD] /WRG[CONN A PIN A7]

Fault Code:

3145118DAU

Associated CAS:

None

Reporting LRU: Data Acquisition Unit (DAU) 3
System Description: 31-40-00
Schematic Diagram: 31-41-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 31-41-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]
34-61-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

The Data Acquisition Unit (DAU) 3 senses a fault related to the FMS 1/3 A429 relay.

Possible Causes:

  • FMS 1/3 A429 Relay 1 (K33)
  • Secondary-Power Distribution Assembly (SPDA) 1 (A13)
  • Data Acquisition Unit (DAU) 3 (A30)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Connect Electrical Power to the Aircraft AMM 24-00-00-861-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Remove the Electrical Power from the Aircraft AMM 24-00-00-861-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Electrical/Electronic Safety Precautions AMM 24-00-00-910-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Electrostatic Discharge Safety Precautions AMM 24-00-00-910-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Secondary-Power Distribution Assemblies AMM 24-62-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Secondary-Power Distribution Assemblies AMM 24-62-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Data Acquisition Units (DAU) AMM 31-42-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Data Acquisition Units (DAU) AMM 31-42-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Lamp Test Relay AMM 31-42-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Lamp Test Relay AMM 31-42-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to Active Faults AMM 45-45-00-970-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to Stored Faults AMM 45-45-00-970-803 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the External Avionics-Compartment
Access-Panel (140BB)
AMM 52-45-11-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the External Avionics-Compartment
Access-Panel (140BB)
AMM 52-45-11-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Safety Precautions - Maintenance Practices - ALL SPM 20-00-01-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Replacement of the Plug-In Relay SPM 20-13-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Replace the FMS 1/3 A429 relay 1. Is the fault still present?

    1. If NO, do close out.
    2. If YES, continue with the next step.

  2. Remove the DAU 3 and disconnect the electrical connector A13P2 from SPDA 1. Perform a continuity check as follows:

    From To Result
    A30AP1-A7 A13P2-e

    1. If there is no continuity, repair or replace defective wiring as required and do close out.
    2. If there is continuity, continue with next step.

  3. Perform a continuity check as follows:

    From To Result
    A30AP1-A7 Ground

    1. If there is continuity, repair or replace defective wiring as required and do close out.
    2. If there is no continuity, continue with next step.

  4. Swap the DAU 3 with DAU 1. Is the fault still present?

    1. If NO, replace DAU 3 and do close out.
    2. If YES, continue with next step.

  5. Replace the SPDA 1.
  6. Do close out.