08/23/19
Message Overview:
Fault Message:
ACSC_1A/WRG/DAU #3 INACTIVE
Fault Code:
3145155DAU
Associated CAS:
| Reporting LRU: | Data Acquisition Unit (DAU) 3 |
| System Description: | 21-52-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Fault Description:
Data Acquistion Unit (DAU) 3 is reporting that one of the following is at fault:
- The DAU 3 ARINC Receiver (internal failure)
- The Transmitter of the Line Replaceable Unit (LRU) wired to DAU 3 (see below for LRU identification)
- ARINC wiring interfacing DAU 3 and LRU
According to DAU 3 position, LRU is
Possible Causes:
- Data Acquisition Unit (DAU) 3 (A30)
- Air Conditioning System Controller (ACSC) 1 (A87)
Troubleshooting Tips: