background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults By CAIMS By Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

08/02/19

Message Overview:

Fault Message:

RVTEXLO 1/WRG/DAU 4

Fault Code:

3147042DAU

Associated CAS:

None

Reporting LRU: Data Acquisition Unit (DAU) 4
System Description: 31-40-00
Schematic Diagram: 31-42-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
32-51-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 31-42-04 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

The Data Acquisition Unit (DAU 4) senses that the excitation for the Rudder Pedal Position Transducer on CH A is out of range.

Possible Causes:

  • Rudder Pedal Dual Rotary Variable Differential Transducer (RVDT) (MT219)
  • Data Acquisition Unit (DAU) 4 (A31)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Electrical/Electronic Safety Precautions AMM 24-00-00-910-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Control Column Rotary-Variable- Differential-Transformer (RVDT) AMM 27-31-27-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Control Column Rotary-Variable- Differential-Transformer (RVDT) AMM 27-31-27-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Data Acquisition Units (DAU) AMM 31-42-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Data Acquisition Units (DAU) AMM 31-42-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to Stored Faults AMM 45-45-00-970-803 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Safety Precautions - Maintenance Practices - ALL SPM 20-00-01-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Remove the DAU 4 to get access to the connector A31AP1 and rudder pedal dual transducer to get access to the connector MT219P1. Perform a continuity check as follows:

    From To Result
    A31AP1-B7 MT219P1-6
    A31AP1-C7 MT219P1-7

    1. If there is no continuity, repair or replace defective wiring as required and do close out.
    2. If there is continuity, continue with next step.

  2. Perform a continuity check as follows:

    From To Result
    A31AP1-B7 Ground
    A31AP1-C7 Ground

    1. If there is continuity, repair or replace defective wiring as required and do close out.
    2. If there is no continuity, continue with next step.

  3. Swap DAU 4 with DAU 2.

    1. If system checks are good, replace DAU 4 and do close out.
    2. If fault remains, continue with next step.

  4. Replace the Rudder Pedal Dual Transducer.
  5. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.