08/23/19
Message Overview:
Fault Message:
BMC_2B/WRG/DAU #4 INACTIVE
Fault Code:
3147050DAU
Associated CAS:
| Reporting LRU: | Data Acquisition Unit (DAU) 4 |
| System Description: | 36-11-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Fault Description:
Data Acquisition Unit (DAU) 4 is reporting that one of the following is at fault:
- The DAU ARINC Receiver (internal failure)
- The Transmitter of the Line Replaceable Unit (LRU) wired to DAU 4 (see below for LRU identification)
- ARINC wiring interfacing DAU 4 and LRU
According to DAU 4 position, LRU is
Possible Causes:
- Data Acquisition Unit (DAU) 4 (A31)
- Bleed Management Controller (BMC) 2 (A70)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
None
Troubleshooting Recommendations:
None