08/23/19
Message Overview:
Fault Message:
DAU #4 [ANA CARD] FAULT
Fault Code:
3147053DAU
Associated CAS:
| Reporting LRU: | Data Acquisition Unit (DAU) 4 |
| System Description: | 31-40-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Fault Description:
With Data Acquisition Unit (DAU) P/N 10604B01M05 or prior, there are two possible conditions to this fault:
- An Resistance Temperature Detector (RTD) input is out of range on the HI side
- The Analog Card has failed
With DAU P/N 10604B02M07 or subsequent possible conditions to this fault:
- The Data Acquisition Unit (DAU) is reporting that its Analog Card has fa
Possible Causes:
- Data Acquisition Unit (DAU) 4 (A31)
- Resistance Temperature Detector
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
None
Troubleshooting Recommendations:
None