08/05/19
Message Overview:
Fault Message:
IAC 2 - INTERNAL FWC/EFIS FAULT
Fault Code:
3151005FW2
Associated CAS:
| Reporting LRU: | Integrated Avionics Computer (IAC) 2 |
| System Description: | 31-50-00 |
| Schematic Diagram: | 31-41-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 31-52-04 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Integrated Avionics Computer (IAC) 2 cannot supply its usual aural warnings and display functions.
Possible Causes:
- Integrated Avionics Computer (IAC) 2 (A10)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-45-0065 - CAIMS Nuisance Fault Messages
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to System Diagnostics | AMM 45-45-00-970-804 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Integrated Maintenance Test (IMT) Fault Code Look-Up |
AMM 45-45-00-970-826 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- On the CAIMS PMAT, get access to system diagnostics and do the FWC Discrete Input Test, IAC EDS/Core Test, and Xside Aural Warnings Test.
- After each test is completed, look for the TEST RESULTS page and record the fault type and code(s) for each IMT fault.
- Perform the IMT fault code look-up procedure to find the applicable troubleshooting procedures.
- Carry out troubleshooting procedures.
- Do close out.