08/05/19
Message Overview:
Fault Message:
IAC 3 - INTERNAL FWC/EFIS FAULT
Fault Code:
3151005FW3
Associated CAS:
| Reporting LRU: | Integrated Avionics Computer (IAC) 3 |
| System Description: | 31-40-00 |
| Schematic Diagram: | 31-41-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 31-41-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Integrated Avionics Computer (IAC) 3 cannot supply its usual aural warnings and display functions.
Possible Causes:
- Integrated Avionics Computer (IAC) 3 (A12)
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-45-0065 - CAIMS Nuisance Fault Messages
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Remove the Electrical Power from the Aircraft | AMM 24-00-00-861-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to System Diagnostics | AMM 45-45-00-970-804 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Integrated Maintenance Test (IMT) Fault Code Look-Up |
AMM 45-45-00-970-826 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Access CAIMS Systems Diagnostics and perform the FWC Discrete Input Test, IAC EDS/Core Test and Xside Aural Warnings Test.
- After each IMT test is completed, record the active IMT code from the TEST RESULTS page.
- Perform the Integrated Maintenance Test (IMT) fault code look-up to find the applicable troubleshooting procedures.
- Do close out.