08/06/19
Message Overview:
Fault Message:
TREND MEMORY FULL (IAC2)
Fault Code:
3151017FW2
Associated CAS:
| Reporting LRU: | Integrated Avionics Computer (IAC) 2 |
| System Description: | 31-40-00 |
| Schematic Diagram: | 31-41-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 31-41-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Integrated Avionics Computer (IAC) Engine Trend memory is full. New data will overwrite older data.
Possible Causes:
- Integrated Avionics Computer (IAC) 2 (A10)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Remove the Electrical Power from the Aircraft | AMM 24-00-00-861-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the Integrated Avionics Computer (IAC) System |
AMM 31-41-00-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Download the Engine Trend data from the IAC.
- Do close out.