08/07/19
Message Overview:
Fault Message:
LGECU A/WRG/LDG GR SEL VALVE #3 UP
Fault Code:
3230193EL
Associated CAS:
| Reporting LRU: | Landing Gear Electronic Control Unit (LG ECU) |
| System Description: | 32-31-00 |
| Schematic Diagram: | 32-31-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 32-31-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Landing Gear Electronic Control Unit (LG ECU) has detected a failure with the Landing Gear Selector Valve 3 UP command signal going to the valve. This fault is normally internal to the LGECU but could be external.
Possible Causes:
- Landing Gear Selector Valve 3 (L17)
- Landing Gear Control Handle (S3)
- Landing Gear Electronic Control Unit (LGECU) (A52)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Landing-Gear Control Handle | AMM 32-31-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Landing-Gear Control Handle | AMM 32-31-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Landing-Gear Electronic Control-Unit (LG ECU) | AMM 32-31-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Landing-Gear Electronic Control-Unit (LG ECU) | AMM 32-31-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the No. 3 System Landing-Gear Selector-Valve | AMM 32-31-15-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the No. 3 System Landing-Gear Selector-Valve | AMM 32-31-15-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Re-rack LGECU.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Perform wiring checks of the Landing Gear Selector Valve 3 Up Command wires between the LGECU connector A52BP1 and the Landing Gear Selector Valve.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Perform wiring checks of the Landing Gear Selector Valve 3 Up Command (Solenoid A) wire between the Landing Gear Control Handle and the Landing Gear Selector Valve.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Perform wiring checks between the Landing Gear Control Handle and GND.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Measure the Landing Gear Selector Valve 3 Solenoid A resistance - between 57 and 65 Ohms at 68°F (20°C).
- If resistance is within range, go to step 7.
- If resistance is out of range, continue with next step.
- Swap Landing Gear Selector Valve 3 with Landing Gear Selector Valve 2.
- If system checks are good, replace Landing Gear Selector Valve 3 and do close out.
- If fault remains, continue with next step.
- Replace Landing gear control handle.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace LGECU.
- Do close out.