08/08/19
Message Overview:
Fault Message:
SPC/WRG/LGECU A (MLG WOW IND)2
Fault Code:
3230238EL
Associated CAS:
| Reporting LRU: | Landing Gear Electronic Control Unit (LG ECU) |
| System Description: | 32-31-00 |
| Schematic Diagram: | 32-31-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 32-31-04 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Landing Gear Electronic Control Unit (LG ECU) has detected a failure in the Stall Protection Computer (SPC) wiring.
Possible Causes:
- Stall Protection Computer (SPC) (A40)
- Landing Gear Electronic Control Unit (LG ECU) (A52)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-45-0065 - CAIMS Nuisance Fault Messages
Forum Articles/Infoservice/Newsletter: None
NOTE: May be a nuisance Fault during power up. Reset the LGECU circuit breakers.
Quick Links:
| Removal of the Stall Protection Computer | AMM 27-32-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Stall Protection Computer | AMM 27-32-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Landing-Gear Electronic Control-Unit (LG ECU) |
AMM 32-31-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Landing-Gear Electronic Control-Unit (LG ECU) |
AMM 32-31-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Reset the circuit breakers.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Re-seat the LGECU.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Re-seat the SPC.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Perform wiring checks of the Main Gear WOW wire between the LGECU connector A52BP1 and the SPC connector A40BP1 and check the loads for failure.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace LGECU.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace SPC.
- Do close out.