08/29/19
Message Overview:
Fault Message:
SPDA 4/WRG/LGECU A (28VDC PWR LOW)
Fault Code:
3230268EL
Associated CAS:
| Reporting LRU: | Landing Gear Electronic Control Unit (LGECU) |
| System Description: | 32-31-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Fault Description:
External fault can occur if aircraft power (28 VDC BUS) is not equal to or greater than 20.5 VDC for more than 5 seconds.
Fault is usually caused by:
- 28 VDC BUS PWR < 14.75 +/- 0.75 VDC
- CKT BRKR OPEN OR DAMAGED
- DAMAGED 28 VDC POWER BUS (WRG)
Possible Causes:
- Landing Gear Electronic Control Unit (LGECU) (A52)
- Secondary Power Distribution Assemblies (SPDA) 4 (A16)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
None
Troubleshooting Recommendations:
None