08/29/19
Message Overview:
Fault Message:
SPDA 3/WRG/LGECU A (BATT PWR LOW)
Fault Code:
3230269EL
Associated CAS:
| Reporting LRU: | Landing Gear Electronic Control Unit (LGECU) |
| System Description: | 32-31-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Fault Description:
Fault can occur if aircraft power (BATT BUS) is not equal to or greater than 20.5 VDC for more than 5 seconds.
Fault is usually caused by:
- BATT BUS PWR < 14.75 +/- 0.75 VDC
- CKT BRKR OPEN OR DAMAGED
- DAMAGED BATT POWER BUS (WIRING) AT SPDA 3, FOR BATT BUS
Possible Causes:
- Landing Gear Electronic Control Unit (LGECU) (A52)
- Secondary Power Distribution Assemblies (SPDA) 3 (A15)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
None
Troubleshooting Recommendations:
None