08/29/19
Message Overview:
Fault Message:
EMSCDU1/WRG/LGECU B (MLG WOW IND)
Fault Code:
3231204EL
Associated CAS:
| Reporting LRU: | Landing Gear Electronic Control Unit (LG ECU) |
| System Description: | 32-31-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Fault Description:
External fault usually caused by:
- Damaged/defective wiring
- Too much load current
- Load not connected
- Load has open-circuit
- Load has short-circuit to ground
Fault related to more than one load and other fault messages:
- SPC/WRG/LGECU
Possible Causes:
- Landing Gear Electronic Control Unit (LG ECU) (A52)
- Electrical Management System Control and Display Unit (EMS CDU) 1 (A94)
- Stall Protection Computer (SPC) (A40)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
None
Troubleshooting Recommendations:
None