Message Overview:
Fault Message:
WINDOW ONE SENSOR FAILED
Fault Code:
3000106IN
Associated CAS:
| Reporting LRU: | Enhanced Vision System Heater Controller (EVSHC) |
| System Description: | 34-33-00 |
| Schematic Diagram: | 34-33-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 34-33-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
One Infra Red Window Temperature Sensor has been detected either shorted (< 74 Ω) or opened (> 136 Ω) by the Enhanced Vision System Heater Controller (EVSHC).
Possible Causes:
- Infra Red Window (IRW) (A320)
- Enhanced Vision System Heater Controller (EVSHC) (A315)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Enhanced Vision System (EVS) Infrared Window (IRW) |
AMM 34-33-06-000-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Enhanced Vision System (EVS) Infrared Window (IRW) |
AMM 34-33-06-400-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Enhanced Vision System (EVS) Heater Controller |
AMM 34-33-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Enhanced Vision System (EVS) Heater Controller |
AMM 34-33-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Perform wiring checks between EVSHC and IRW as follow:
NOTE: Resistance between sensor terminals refer to Window Sensor Resistance vs Temp chart.From To Result A315P1-a A320P1-A A315P1-Z A320P1-B (RTN) A315P1-Y A320P1-J A315P1-X A320P1-K (RTN) - If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace IRW.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace EVSHC.
- Do close out.