background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults By CAIMS By Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

08/20/19

Message Overview:

Fault Message:

EVSHC INTERNAL WINDOW TEMP ANALYSIS

Fault Code:

3000135IN

Associated CAS:

None

Reporting LRU: Enhanced Vision System Heater Controller (EVSHC)
System Description: 34-33-00
Schematic Diagram: 34-33-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 34-33-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

Enhanced Vision System Heater Controller (EVSHC) has internal failure.

Possible Causes:

  • Enhanced Vision System Heater Controller (EVSHC) (A315)

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Enhanced Vision System (EVS)
Heater Controller
AMM 34-33-09-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Enhanced Vision System (EVS)
Heater Controller
AMM 34-33-09-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Replace EVSHC.
  2. Do close out.