08/24/19
Message Overview:
Fault Message:
EVS COMMUNICATION/WRG
Fault Code:
3430004EVS
Associated CAS:
| Reporting LRU: | Head-Up-Display (HUD) System |
| System Description: | 34-33-00 |
| Schematic Diagram: | 34-33-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 34-33-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Head-Up-Display System (HUDS) is not able to communicate with the Infrared Sensor Unit (ISU) or the HUD is invalid.
Possible Causes:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Head-Up-Display (HUD) Computer | AMM 34-32-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Head-Up-Display (HUD) Computer | AMM 34-32-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Enhanced Vision System (EVS) - InfraRed Sensor Unit (ISU) |
AMM 34-33-03-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Enhanced Vision System (EVS) - InfraRed Sensor Unit (ISU) |
AMM 34-33-03-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Perform wiring checks between HUDC and ISU as follow:
From To Result A250BP1-J3 A318P1-a A250BP1-K3 A318P1-u A250DP1-G1 A318P1-H A250DP1-H1 A318P1-Z - If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace HUDC.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace ISU.
- Do close out.